版权说明 操作指南
首页 > 成果 > 成果详情

Study on the Coupling Relationship between Thermal Comfort and Urban Center Spatial Morphology in Summer

认领
导出
Link by DOI
反馈
分享
QQ微信 微博
成果类型:
期刊论文
作者:
Yi, Pei;Liu, Luyun;Huang, Yu;Zhang, Minhuan;Liu, Huaiwan;...
通讯作者:
Luyun Liu<&wdkj&>Yu Huang
作者机构:
[Liu, Huaiwan; Yi, Pei; Zhang, Minhuan; Liu, Luyun] Cent South Univ Forestry & Technol, Sch Landscape Architecture, Changsha 410004, Peoples R China.
[Huang, Yu] Nanning Univ, Sch Art & Design, Nanning 530200, Peoples R China.
[Bedra, Komi Bernard] Cent South Univ, Sch Architecture & Art, Changsha 410083, Peoples R China.
通讯机构:
[Luyun Liu; Yu Huang] A
Authors to whom correspondence should be addressed.<&wdkj&>School of Art & Design, Nanning University, Nanning 530200, China<&wdkj&>Authors to whom correspondence should be addressed.<&wdkj&>School of Landscape Architecture, Central South University of Forestry and Technology, Changsha 410004, China
语种:
英文
关键词:
thermal comfort;urban central area;morphological space;UTCI;ENVI-met
期刊:
Sustainability
ISSN:
2071-1050
年:
2023
卷:
15
期:
6
页码:
5084-
基金类别:
Conceptualization, L.L. and P.Y.; methodology, L.L.; software, H.L.; validation, P.Y. and H.L.; investigation, P.Y. and Y.H.; resources, L.L.; writing—original draft preparation, L.L.; writing—review and editing, M.Z. and K.B.B.; supervision, K.B.B. and H.L.; funding acquisition, L.L. All authors have read and agreed to the published version of the manuscript. This research was funded by the National Natural Science Foundation of China, grant number 31901363, the Scientific Innovation Fund for Postgraduates of Central South University of Forestry and Technology, grant number CX202202076, and the Outstanding Youth Project of Hunan Provincial Department of Education, grant number 22B0285.
机构署名:
本校为第一机构
院系归属:
风景园林学院
摘要:
The high-density development of urban centers has worsened outdoor thermal comfort in many cities. In this study, ENVI-met was used to simulate thermal comfort, and the universal thermal climate index (UTCI) and eight urban morphological indicators were calculated at 348 sampling points in the urban center. The correlation results are shown as follows: (1) Thermal comfort is significantly and positively correlated with impervious surface, green area ratio, and sky openness, showing a strong negative correlation with building density, floor area ratio, and shadow hours. (2) The UTCI value decre...

反馈

验证码:
看不清楚,换一个
确定
取消

成果认领

标题:
用户 作者 通讯作者
请选择
请选择
确定
取消

提示

该栏目需要登录且有访问权限才可以访问

如果您有访问权限,请直接 登录访问

如果您没有访问权限,请联系管理员申请开通

管理员联系邮箱:yun@hnwdkj.com