Concrete-filled steel tubular shear wall is a form of steel structure assembled building, which can be used in high-rise and super high-rise buildings, and it has a great development prospect. Applying the basic concept of full-section plasticity, four basic assumptions are proposed. Based on these four basic assumptions, the formulas for calculating the height and bending capacity of the concrete compression zone of the 1-shaped concrete-filled stee...