版权说明 操作指南
首页 > 成果 > 成果详情

A direct solving method for the minimun height of rectangle extended foundation under column that meets the punching requirement

认领
导出
下载 Link by DOI
反馈
分享
QQ微信 微博
成果类型:
期刊论文、会议论文
作者:
Huang, Taihua*;Zhou, Xianyan;Tan, Ping
通讯作者:
Huang, Taihua
作者机构:
[Huang, Taihua; Zhou, Xianyan] Cent South Univ Forestry & Technol, Civil Engn & Mech Inst, Changsha 410004, Hunan, Peoples R China.
[Tan, Ping] City Planning Design Inst Zhuzhou, Zhuzhou 412007, Hunan, Peoples R China.
通讯机构:
[Huang, Taihua] C
Cent South Univ Forestry & Technol, Civil Engn & Mech Inst, Changsha 410004, Hunan, Peoples R China.
语种:
英文
关键词:
Direct solving method;Minimum height of foundation;Punching requirement;Rectangle extended foundation
期刊:
Advanced Materials Research
ISSN:
1022-6680
年:
2013
卷:
639-640
期:
1
页码:
577-580
会议名称:
1st International Conference on Advances in Civil Infrastructure Engineering (ICACIE 2012)
会议论文集名称:
Advanced Materials Research
会议时间:
SEP 15-16, 2012
会议地点:
Changsha, PEOPLES R CHINA
会议主办单位:
[Huang, Taihua;Zhou, Xianyan] Cent South Univ Forestry & Technol, Civil Engn & Mech Inst, Changsha 410004, Hunan, Peoples R China.^[Tan, Ping] City Planning Design Inst Zhuzhou, Zhuzhou 412007, Hunan, Peoples R China.
会议赞助商:
Cent S Univ Forestry & Technol, Hunan Univ, Univ So California, Univ California Davis, Sapienza Univ Rome, Natl Nat Sci Fdn, Cent S Univ, Xiangtan Univ, Changsha Univ Sci & Technol, Hunan Univ Sci & Technol, Hunan Univ Technol, Univ S China, Survey & Design Inst, Hunan Prov Commun Plann, Foshan Highway & Bridge Construct Co Ltd
主编:
Zhou, XY He, GJ Fan, YL Xiao, Y Kunnath, SK Monti, G
出版地:
KREUZSTRASSE 10, 8635 DURNTEN-ZURICH, SWITZERLAND
出版者:
TRANS TECH PUBLICATIONS LTD
ISBN:
978-3-03785-584-3
机构署名:
本校为第一且通讯机构
院系归属:
土木工程学院
摘要:
To meet the punching requirement of rectangle extended foundation under column, it is common practice to assume foundation's height first, and then use the formula to check according to the current code. If the foundation's height is not suitable, set it again to check until a suitable value. It is found that the minimum height of rectangle extended foundation under column can be solved directly, and all larger than the minimum height can meet the punching requirement through analysis program taking MATLAB as a platform for ever...